BIM Asset Data Completion Across All Levels and Phases
Tracks how the overall and per-category completion has moved across each refresh of the BIM data. Hover for the exact date and percentage; expand the snapshot list below to see every recorded point.
Click a bar to drill into that category.
Click a phase name to filter by phase. Click a category cell to drill the asset table to that slice.
Click a level name to filter the whole dashboard. Click a category cell to drill the asset table to that slice.
| Basic | FM | BOS | Element Specific | Uncategorised | All | |
|---|---|---|---|---|---|---|
| Level B2 | — | — | — | — | — | — |
| Level B1 | — | — | — | — | — | — |
| Level 00 | — | — | — | — | — | — |
| Level 00M | — | — | — | — | — | — |
| Level 01 | — | — | — | — | — | — |
| Level 02 | — | — | — | — | — | — |
| Level 03 | — | — | — | — | — | — |
| Level 04 | — | — | — | — | — | — |
| Level 05 | — | — | — | — | — | — |
| Level 06 | 75% | 0% | 69% | — | 58% | 47% |
| Level 07 | — | — | — | — | — | — |
| Level 08 | — | — | — | — | — | — |
| Level 09 | — | — | — | — | — | — |
| Level 10 | — | — | — | — | — | — |
| Level 11 | 86% | 8% | 62% | — | 100% | 62% |
| Level 12 | 87% | 0% | 33% | — | 75% | 53% |
| SSY 17.900 | — | — | — | — | — | — |
| Datum | — | — | — | — | — | — |
| (no level) | — | — | — | — | — | — |
One row per BIM element. Reflects the active filters. Click a row to open that asset’s full record.
| File | Phase | Level | Asset Category | Asset Code | Element ID | GUID | IFC GUID | Row # | Asset Description | Family | Type | Maint. | Basic | FM | BOS | Element-Spec | Uncat. | Overall |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Duct Accessories | VCD-2060010 | 10161703 | 61c8b532-51b3-46ea-a8c2-3418bef36292-009b0431 | — | 24 | Rectangular attenuators | HL_Attenuator_RecBodyRecCon2 | Generic Cross Talk | No | 87% | 0% | 100% | — | 50% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Duct Accessories | — | 10161709 | 61c8b532-51b3-46ea-a8c2-3418bef36292-009b0770 | — | 25 | Rectangular attenuators | HL_Attenuator_RecBodyRecCon2 | Generic Cross Talk | No | 67% | 0% | 67% | — | 50% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Duct Accessories | — | 10161712 | 61c8b532-51b3-46ea-a8c2-3418bef36292-009b0787 | — | 26 | Rectangular attenuators | HL_Attenuator_RecBodyRecCon2 | Generic Cross Talk | No | 67% | 0% | 67% | — | 50% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Duct Accessories | VCD-2060010 | 10161715 | 61c8b532-51b3-46ea-a8c2-3418bef36292-009b079e | — | 27 | Rectangular attenuators | HL_Attenuator_RecBodyRecCon2 | Generic Cross Talk | No | 87% | 0% | 100% | — | 50% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Duct Accessories | VCD-2060018 | 10161718 | 61c8b532-51b3-46ea-a8c2-3418bef36292-009b0ac1 | — | 28 | Rectangular attenuators | HL_Attenuator_RecBodyRecCon2 | Generic Cross Talk | No | 87% | 0% | 100% | — | 50% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Duct Accessories | VCD-2060010 | 10161722 | 61c8b532-51b3-46ea-a8c2-3418bef36292-009b0df2 | — | 29 | Rectangular attenuators | HL_Attenuator_RecBodyRecCon2 | Generic Cross Talk | No | 87% | 0% | 100% | — | 50% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Duct Accessories | VCD-2060029 | 10162442 | 61c8b532-51b3-46ea-a8c2-3418bef36292-009b110a | — | 30 | Rectangular attenuators | HL_Attenuator_RecBodyRecCon2 | Generic Cross Talk | No | 87% | 0% | 100% | — | 50% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Duct Accessories | VCD-2060007 | 10163235 | 61c8b532-51b3-46ea-a8c2-3418bef36292-009b1423 | — | 31 | Rectangular attenuators | HL_Attenuator_RecBodyRecCon2 | Generic Cross Talk | No | 87% | 0% | 100% | — | 50% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Duct Accessories | VCD-2060038 | 10164028 | 61c8b532-51b3-46ea-a8c2-3418bef36292-009b173c | — | 32 | Rectangular attenuators | HL_Attenuator_RecBodyRecCon2 | Generic Cross Talk | No | 87% | 0% | 100% | — | 50% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Duct Accessories | VCD-2060035 | 10164823 | 61c8b532-51b3-46ea-a8c2-3418bef36292-009b1a57 | — | 33 | Rectangular attenuators | HL_Attenuator_RecBodyRecCon2 | Generic Cross Talk | No | 87% | 0% | 100% | — | 50% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Duct Accessories | VCD-2060036 | 10165615 | 61c8b532-51b3-46ea-a8c2-3418bef36292-009b1d6f | — | 34 | Rectangular attenuators | HL_Attenuator_RecBodyRecCon2 | Generic Cross Talk | No | 87% | 0% | 100% | — | 50% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Duct Accessories | VCD-2060037 | 10166407 | 61c8b532-51b3-46ea-a8c2-3418bef36292-009b2087 | — | 35 | Rectangular attenuators | HL_Attenuator_RecBodyRecCon2 | Generic Cross Talk | No | 87% | 0% | 100% | — | 50% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8575841 | 456064e2-9200-4308-8ef6-3d8f329ad786-0082c896 | — | 3868 | Standard socket outlets | HL_RotaryIsolator_WallSurfaceWeatherproof | 4 Pole 016A | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10725820 | 72960570-82d0-4eee-b439-0f0bf9b1a395-00a304d3 | — | 3869 | Standard socket outlets | HL_RotaryIsolator_WallSurfaceWeatherproof | 4 Pole 016A | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7453746 | 3c09dd9a-3c33-4f1e-83a0-14b8e353ece7-0071bc32 | — | 3900 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8558322 | 67c360e1-e1d4-4db5-aacf-640735e3c9d8-00828247 | — | 3901 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8578621 | 555ad80b-9818-4343-99f5-f534ec449ff5-0082e63d | — | 3902 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9608820 | 053b3512-7815-4d60-9e93-f51c9dd1c6c4-0092818b | — | 3917 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Unswitched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9608821 | 053b3512-7815-4d60-9e93-f51c9dd1c6c4-009281bd | — | 3918 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Unswitched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8575898 | 555ad80b-9818-4343-99f5-f534ec449ff5-0082d968 | — | 3935 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9595000 | 799dd4e7-af85-4d17-befe-1c0e705dc692-0092458a | — | 3943 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10964552 | 508c2a91-c890-47ea-bf05-f5b7fffcbd54-00a74e48 | — | 3948 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10964688 | 508c2a91-c890-47ea-bf05-f5b7fffcbd54-00a74ed0 | — | 3949 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10964752 | 508c2a91-c890-47ea-bf05-f5b7fffcbd54-00a74f10 | — | 3950 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10964788 | 508c2a91-c890-47ea-bf05-f5b7fffcbd54-00a74f34 | — | 3951 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8629146 | df0a1036-0cc7-4c4f-b2ee-635b7a71def9-00834669 | — | 3953 | Standard socket outlets | HL_SocketOutlet_WallRecessed_BB | Single Gang Type Back Box | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9608834 | 053b3512-7815-4d60-9e93-f51c9dd1c6c4-00928924 | — | 3954 | Standard socket outlets | HL_SocketOutlet_WallRecessed1 | 1 Gang Unswitched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9608836 | 053b3512-7815-4d60-9e93-f51c9dd1c6c4-0092895e | — | 3955 | Standard socket outlets | HL_SocketOutlet_WallRecessed1 | 1 Gang Unswitched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7453724 | 3c09dd9a-3c33-4f1e-83a0-14b8e353ece7-0071bc1c | — | 3956 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7453743 | 3c09dd9a-3c33-4f1e-83a0-14b8e353ece7-0071bc2f | — | 3957 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7453768 | 3c09dd9a-3c33-4f1e-83a0-14b8e353ece7-0071bc48 | — | 3958 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7604207 | 95312008-47bd-4482-8fc5-f5bc14c8f265-007407ef | — | 3959 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8126974 | fa04c54d-1610-49dc-9da9-68f0e6a098d6-007c01fe | — | 3960 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8575900 | 555ad80b-9818-4343-99f5-f534ec449ff5-0082da99 | — | 3961 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8577664 | 555ad80b-9818-4343-99f5-f534ec449ff5-0082e280 | — | 3962 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8579450 | 555ad80b-9818-4343-99f5-f534ec449ff5-0082e97a | — | 3963 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8579527 | 555ad80b-9818-4343-99f5-f534ec449ff5-0082e9c7 | — | 3964 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9517644 | 924d2901-f211-46af-9794-520467fc39b8-00912fb4 | — | 3970 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9595048 | 799dd4e7-af85-4d17-befe-1c0e705dc692-00924af8 | — | 3974 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9622702 | 888f2947-f5d8-4802-afab-d401be5d4853-0092c959 | — | 3975 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9696328 | 656b7791-de7e-48c7-bcdd-7ef49fb07746-0093cc42 | — | 3977 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9912821 | 974198fb-491e-480f-8b7e-4f5a6e95e93a-009717e8 | — | 3978 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9912823 | 974198fb-491e-480f-8b7e-4f5a6e95e93a-009717f7 | — | 3979 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9920026 | e96a4585-0409-4e34-8771-8ef808bb7596-00971fce | — | 3980 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10725799 | 72960570-82d0-4eee-b439-0f0bf9b1a395-00a2fc46 | — | 3981 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10725801 | 72960570-82d0-4eee-b439-0f0bf9b1a395-00a2fc86 | — | 3982 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10725804 | 72960570-82d0-4eee-b439-0f0bf9b1a395-00a2fdca | — | 3983 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10725806 | 72960570-82d0-4eee-b439-0f0bf9b1a395-00a2fdd4 | — | 3984 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10725807 | 72960570-82d0-4eee-b439-0f0bf9b1a395-00a2fe06 | — | 3985 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10725808 | 72960570-82d0-4eee-b439-0f0bf9b1a395-00a2ff07 | — | 3986 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10725810 | 72960570-82d0-4eee-b439-0f0bf9b1a395-00a2ff45 | — | 3987 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10725811 | 72960570-82d0-4eee-b439-0f0bf9b1a395-00a30178 | — | 3988 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7453727 | 3c09dd9a-3c33-4f1e-83a0-14b8e353ece7-0071bc1f | — | 3990 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Unswitched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7453729 | 3c09dd9a-3c33-4f1e-83a0-14b8e353ece7-0071bc21 | — | 3991 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Unswitched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7453752 | 3c09dd9a-3c33-4f1e-83a0-14b8e353ece7-0071bc38 | — | 3992 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Unswitched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7453754 | 3c09dd9a-3c33-4f1e-83a0-14b8e353ece7-0071bc3a | — | 3993 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Unswitched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7453755 | 3c09dd9a-3c33-4f1e-83a0-14b8e353ece7-0071bc3b | — | 3994 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Unswitched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8622746 | df0a1036-0cc7-4c4f-b2ee-635b7a71def9-00831f59 | — | 3995 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 1 Gang Unswitched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7453286 | 3c09dd9a-3c33-4f1e-83a0-14b8e353ece7-0071ba66 | — | 3996 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7453356 | 3c09dd9a-3c33-4f1e-83a0-14b8e353ece7-0071baac | — | 3997 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7453733 | 3c09dd9a-3c33-4f1e-83a0-14b8e353ece7-0071bc25 | — | 3998 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7453770 | 3c09dd9a-3c33-4f1e-83a0-14b8e353ece7-0071bc4a | — | 3999 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 7604186 | 95312008-47bd-4482-8fc5-f5bc14c8f265-007407da | — | 4000 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8361970 | ef8d3a5c-3b97-4a03-9bde-4884df26bfac-007f97f2 | — | 4001 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8558323 | 67c360e1-e1d4-4db5-aacf-640735e3c9d8-0082825f | — | 4002 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8558325 | 67c360e1-e1d4-4db5-aacf-640735e3c9d8-00828261 | — | 4003 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8575834 | 456064e2-9200-4308-8ef6-3d8f329ad786-0082c615 | — | 4004 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8622742 | df0a1036-0cc7-4c4f-b2ee-635b7a71def9-00831d3b | — | 4005 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8684340 | a842612c-4078-44c5-9ff4-36e44c059584-00845caf | — | 4006 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9434047 | 28484f7d-279c-4e4f-8df7-a2788e3da77c-008fd18a | — | 4008 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9522943 | 13200ef2-2eaf-4910-93f5-eb14ddd9facb-00913b49 | — | 4009 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9522945 | 13200ef2-2eaf-4910-93f5-eb14ddd9facb-00913ba2 | — | 4010 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9522946 | 13200ef2-2eaf-4910-93f5-eb14ddd9facb-00913baa | — | 4011 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9595007 | 799dd4e7-af85-4d17-befe-1c0e705dc692-009246ce | — | 4012 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9595034 | 799dd4e7-af85-4d17-befe-1c0e705dc692-00924903 | — | 4013 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9595045 | 799dd4e7-af85-4d17-befe-1c0e705dc692-009249fe | — | 4014 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9595060 | 799dd4e7-af85-4d17-befe-1c0e705dc692-00924b39 | — | 4015 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9595070 | 799dd4e7-af85-4d17-befe-1c0e705dc692-00924bcb | — | 4016 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9601288 | 28ce400c-a2bc-4a80-a715-74bc8d0e61d0-00928108 | — | 4018 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9601559 | 28ce400c-a2bc-4a80-a715-74bc8d0e61d0-00928217 | — | 4019 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | LEVEL 06 - SSL | Electrical Fixtures | — | 9601574 | 28ce400c-a2bc-4a80-a715-74bc8d0e61d0-00928226 | — | 4020 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | LEVEL 06 - SSL | Electrical Fixtures | — | 9601578 | 28ce400c-a2bc-4a80-a715-74bc8d0e61d0-0092822a | — | 4021 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9608777 | 053b3512-7815-4d60-9e93-f51c9dd1c6c4-009279e8 | — | 4022 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9611244 | c85c29c7-926c-4246-815f-25fbd35bfcc7-009282d3 | — | 4023 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9696354 | 656b7791-de7e-48c7-bcdd-7ef49fb07746-0093d436 | — | 4024 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9696402 | 30d47780-b4ed-4bd1-ac40-4086c0ef4c94-0093e336 | — | 4025 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9696462 | 30d47780-b4ed-4bd1-ac40-4086c0ef4c94-0093eeba | — | 4026 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9696464 | 30d47780-b4ed-4bd1-ac40-4086c0ef4c94-0093ef20 | — | 4027 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9707607 | 33356b9d-30f3-4d78-a612-257e165a0b86-00942057 | — | 4028 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9876443 | 317d4c3f-033f-436d-b0e1-82125c0ea0b7-0096b3db | — | 4029 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9876552 | 317d4c3f-033f-436d-b0e1-82125c0ea0b7-0096b448 | — | 4030 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9876589 | 317d4c3f-033f-436d-b0e1-82125c0ea0b7-0096b46d | — | 4031 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9876752 | 317d4c3f-033f-436d-b0e1-82125c0ea0b7-0096b510 | — | 4032 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9876881 | 317d4c3f-033f-436d-b0e1-82125c0ea0b7-0096b591 | — | 4033 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9878640 | 317d4c3f-033f-436d-b0e1-82125c0ea0b7-0096bc70 | — | 4034 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9878736 | 317d4c3f-033f-436d-b0e1-82125c0ea0b7-0096bcd0 | — | 4035 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10049970 | a8904eb4-b69a-46e4-9a5d-9dd0c88487c0-0099411b | — | 4036 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10068958 | 4d10d1d4-0f6e-4395-8c6c-a45e30b1e7e3-009992c1 | — | 4037 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10279336 | 8f172de2-6c77-487c-abf2-e47bd832de51-009cd7d8 | — | 4038 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10564787 | f44c24c3-6ddb-4df4-834a-310de7104f1a-00a129c0 | — | 4039 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10564788 | f44c24c3-6ddb-4df4-834a-310de7104f1a-00a129d5 | — | 4040 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10725815 | 72960570-82d0-4eee-b439-0f0bf9b1a395-00a302c4 | — | 4041 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10725817 | 72960570-82d0-4eee-b439-0f0bf9b1a395-00a30354 | — | 4042 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10725906 | e345b875-f613-4ab5-8090-87c5aeae64ff-00a3aa10 | — | 4043 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10763311 | 838c2287-76ed-4529-9eb1-64f422546b1a-00a43428 | — | 4044 | Standard socket outlets | HL_SocketOutlet_WallRecessed3 | 2 Gang Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10453676 | 495f0952-21f4-4c65-ac63-93ad397e4fb5-009f82ac | — | 4090 | Standard socket outlets | NON Corp GEN_Data_Outlet | Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 10453725 | 495f0952-21f4-4c65-ac63-93ad397e4fb5-009f82dd | — | 4091 | Standard socket outlets | NON Corp GEN_Data_Outlet | Switched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8504043 | 660fc3c9-7703-4035-843a-c0cdc56931c9-0081abcf | — | 4092 | Standard socket outlets | NON Corp GEN_Data_Outlet | Unswitched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8504045 | 660fc3c9-7703-4035-843a-c0cdc56931c9-0081abdf | — | 4093 | Standard socket outlets | NON Corp GEN_Data_Outlet | Unswitched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8558352 | 67c360e1-e1d4-4db5-aacf-640735e3c9d8-00828639 | — | 4094 | Standard socket outlets | NON Corp GEN_Data_Outlet | Unswitched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8558354 | 67c360e1-e1d4-4db5-aacf-640735e3c9d8-00828680 | — | 4095 | Standard socket outlets | NON Corp GEN_Data_Outlet | Unswitched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | LEVEL 06 - SSL | Electrical Fixtures | — | 9707508 | 7ae934a6-480c-4c46-8390-bd45d3cdf2b0-0092b38f | — | 4096 | Standard socket outlets | NON Corp GEN_Data_Outlet | Unswitched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | LEVEL 06 - SSL | Electrical Fixtures | — | 9707511 | 7ae934a6-480c-4c46-8390-bd45d3cdf2b0-0092b483 | — | 4097 | Standard socket outlets | NON Corp GEN_Data_Outlet | Unswitched | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9623782 | 888f2947-f5d8-4802-afab-d401be5d4853-0092d8e6 | — | 4158 | Standard socket outlets | PD_ELFc_Electrical-Fixture_Socket-Commando-TPN_v22.0.1 | Commando Socket TPN | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9623784 | 888f2947-f5d8-4802-afab-d401be5d4853-0092d8e8 | — | 4159 | Standard socket outlets | PD_ELFc_Electrical-Fixture_Socket-Commando-TPN_v22.0.1 | Commando Socket TPN | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9623935 | 888f2947-f5d8-4802-afab-d401be5d4853-0092d97f | — | 4160 | Standard socket outlets | PD_ELFc_Electrical-Fixture_Socket-Commando-TPN_v22.0.1 | Commando Socket TPN | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9623936 | 888f2947-f5d8-4802-afab-d401be5d4853-0092d980 | — | 4161 | Standard socket outlets | PD_ELFc_Electrical-Fixture_Socket-Commando-TPN_v22.0.1 | Commando Socket TPN | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9623948 | 888f2947-f5d8-4802-afab-d401be5d4853-0092d98c | — | 4162 | Standard socket outlets | PD_ELFc_Electrical-Fixture_Socket-Commando-TPN_v22.0.1 | Commando Socket TPN | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | — | Level 06 - FFL | Electrical Fixtures | — | 9623949 | 888f2947-f5d8-4802-afab-d401be5d4853-0092d98d | — | 4163 | Standard socket outlets | PD_ELFc_Electrical-Fixture_Socket-Commando-TPN_v22.0.1 | Commando Socket TPN | — | 67% | 0% | 67% | — | 38% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8575835 | 456064e2-9200-4308-8ef6-3d8f329ad786-0082c635 | — | 4174 | Standard socket outlets | PME_IndustrialOutlet_WallSurfaceInterlockedAngled | 2P+E 32A 230V | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 8575842 | 456064e2-9200-4308-8ef6-3d8f329ad786-0082c8d2 | — | 4175 | Standard socket outlets | PME_IndustrialOutlet_WallSurfaceInterlockedAngled | 2P+E 32A 230V | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9434056 | 28484f7d-279c-4e4f-8df7-a2788e3da77c-008fd68a | — | 4183 | Standard socket outlets | S.P&N Control Switch | Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3006 | Phase 3 | Level 06 - FFL | Electrical Fixtures | — | 9608819 | 053b3512-7815-4d60-9e93-f51c9dd1c6c4-00928065 | — | 4184 | Standard socket outlets | S.P&N Control Switch | Switched | No | 80% | 0% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5849338 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005940fa | 0tCTqlmdrB$wjyLzzX_S0K | 7 | Air terminals | HL_DuctCap_ExtractRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845620 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593274 | 0tCTqlmdrB$wjyLzzX_RAQ | 13 | Air terminals | HL_DuctCap_SupplyRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845749 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005932f5 | 0tCTqlmdrB$wjyLzzX_R8R | 14 | Air terminals | HL_DuctCap_SupplyRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845750 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005932f6 | 0tCTqlmdrB$wjyLzzX_R8O | 15 | Air terminals | HL_DuctCap_SupplyRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5851666 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00594a12 | 0tCTqlmdrB$wjyLzzX_Shy | 16 | Air terminals | HL_DuctCap_SupplyRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5851667 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00594a13 | 0tCTqlmdrB$wjyLzzX_Shz | 17 | Air terminals | HL_DuctCap_SupplyRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 6999410 | bee7027b-b3a4-4db6-9809-bdf014a671a6-006acd72 | 2_vm9xiwHDjfW9lV0KpBpK | 18 | Air terminals | HL_DuctCap_SupplyRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845613 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059326d | 0tCTqlmdrB$wjyLzzX_RA3 | 29 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845614 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059326e | 0tCTqlmdrB$wjyLzzX_RA0 | 30 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845615 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059326f | 0tCTqlmdrB$wjyLzzX_RA1 | 31 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845616 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593270 | 0tCTqlmdrB$wjyLzzX_RAU | 32 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845617 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593271 | 0tCTqlmdrB$wjyLzzX_RAV | 33 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845618 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593272 | 0tCTqlmdrB$wjyLzzX_RAS | 34 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845619 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593273 | 0tCTqlmdrB$wjyLzzX_RAT | 35 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845622 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593276 | 0tCTqlmdrB$wjyLzzX_RAO | 36 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845623 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593277 | 0tCTqlmdrB$wjyLzzX_RAP | 37 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845624 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593278 | 0tCTqlmdrB$wjyLzzX_RAM | 38 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845625 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593279 | 0tCTqlmdrB$wjyLzzX_RAN | 39 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845626 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059327a | 0tCTqlmdrB$wjyLzzX_RAK | 40 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845627 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059327b | 0tCTqlmdrB$wjyLzzX_RAL | 41 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845628 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059327c | 0tCTqlmdrB$wjyLzzX_RAI | 42 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845629 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059327d | 0tCTqlmdrB$wjyLzzX_RAJ | 43 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845630 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059327e | 0tCTqlmdrB$wjyLzzX_RAG | 44 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845759 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005932ff | 0tCTqlmdrB$wjyLzzX_R8H | 45 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845760 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593300 | 0tCTqlmdrB$wjyLzzX_RFk | 46 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845761 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593301 | 0tCTqlmdrB$wjyLzzX_RFl | 47 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845762 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593302 | 0tCTqlmdrB$wjyLzzX_RFi | 48 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 7111073 | 4a4fdd3b-c967-41da-abbc-b65c6c4e2024-006c81a1 | 1AJzqxoMT1sgkyjbni8g65 | 49 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 8691385 | 8a104142-4934-4f91-89b4-d65f750a59db-00849eb9 | 2A4452IJHFaOcqrbzrZiTY | 50 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 8856319 | 02260a24-2a90-407d-af75-b8ce96f0144a-008722ff | 029WeaAf10VQzrkCwMTpQr | 51 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 8856320 | 02260a24-2a90-407d-af75-b8ce96f0144a-00872300 | 029WeaAf10VQzrkCwMTpTA | 52 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 8856530 | 02260a24-2a90-407d-af75-b8ce96f0144a-008723d2 | 029WeaAf10VQzrkCwMTpUO | 53 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 8856537 | 02260a24-2a90-407d-af75-b8ce96f0144a-008723d9 | 029WeaAf10VQzrkCwMTpUJ | 54 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 11164916 | c5ed83c5-efb3-49c1-917b-4938e264cecb-00aa5cf4 | 35xOF5xxD9mP5xIJZYpf8$ | 55 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 73% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110005 | 8501267 | e74a31ce-e034-4065-b91c-42755f5f3b0e-0081b813 | 3dIZ7Eu3H0PRaSGdLVteCT | 87 | Air terminals | HL_ExtractGrille_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110004 | 8501295 | e74a31ce-e034-4065-b91c-42755f5f3b0e-0081b82f | 3dIZ7Eu3H0PRaSGdLVteCX | 88 | Air terminals | HL_ExtractGrille_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110003 | 8501950 | e74a31ce-e034-4065-b91c-42755f5f3b0e-0081babe | 3dIZ7Eu3H0PRaSGdLVte6m | 89 | Air terminals | HL_ExtractGrille_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110001 | 8501968 | e74a31ce-e034-4065-b91c-42755f5f3b0e-0081bad0 | 3dIZ7Eu3H0PRaSGdLVte7U | 90 | Air terminals | HL_ExtractGrille_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110002 | 8501969 | e74a31ce-e034-4065-b91c-42755f5f3b0e-0081bad1 | 3dIZ7Eu3H0PRaSGdLVte7V | 91 | Air terminals | HL_ExtractGrille_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110007 | 5845982 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933de | 0tCTqlmdrB$wjyLzzX_RCm | 93 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110008 | 5845983 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933df | 0tCTqlmdrB$wjyLzzX_RCn | 94 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110009 | 5845984 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e0 | 0tCTqlmdrB$wjyLzzX_RCE | 95 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110010 | 5845985 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e1 | 0tCTqlmdrB$wjyLzzX_RCF | 96 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110011 | 5845986 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e2 | 0tCTqlmdrB$wjyLzzX_RCC | 97 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110012 | 5845987 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e3 | 0tCTqlmdrB$wjyLzzX_RCD | 98 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110013 | 5845988 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e4 | 0tCTqlmdrB$wjyLzzX_RCA | 99 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110014 | 5845993 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e9 | 0tCTqlmdrB$wjyLzzX_RC7 | 100 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110015 | 5849308 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005940dc | 0tCTqlmdrB$wjyLzzX_S0o | 101 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110006 | 7884485 | b38a3c8b-6e09-4076-8860-4a1d7537e9b0-007825a3 | 2pYZoBRWb0TeXWIXrrJymJ | 102 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110016 | 8440762 | 9b657c34-f792-47f0-9994-4968684b803a-0080cbba | 2RPNmqzv97y9cKIMXeoqk0 | 103 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110020 | 5845805 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059332d | 0tCTqlmdrB$wjyLzzX_RF3 | 243 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110021 | 5845844 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593354 | 0tCTqlmdrB$wjyLzzX_REw | 244 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110022 | 5845845 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593355 | 0tCTqlmdrB$wjyLzzX_REx | 245 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110023 | 5845846 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593356 | 0tCTqlmdrB$wjyLzzX_REu | 246 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110024 | 5845847 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593357 | 0tCTqlmdrB$wjyLzzX_REv | 247 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110019 | 8479660 | 253350e3-f6aa-49c8-8be9-6e40f7edee51-008163ac | 0bCr3Zzgf9o8lfRa3tR8tz | 248 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110122 | 8507923 | 721f6a28-4a25-462c-b61b-25250538b084-0081d213 | 1o7seeIYL6BBOR9IK5kMAN | 249 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110017 | 8507975 | 721f6a28-4a25-462c-b61b-25250538b084-0081d247 | 1o7seeIYL6BBOR9IK5kMB3 | 250 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110025 | 5845968 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d0 | 0tCTqlmdrB$wjyLzzX_RC_ | 289 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110026 | 5845969 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d1 | 0tCTqlmdrB$wjyLzzX_RC$ | 290 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110028 | 5845971 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d3 | 0tCTqlmdrB$wjyLzzX_RCz | 291 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110030 | 5845973 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d5 | 0tCTqlmdrB$wjyLzzX_RCx | 292 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110031 | 5845974 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d6 | 0tCTqlmdrB$wjyLzzX_RCu | 293 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110032 | 5845975 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d7 | 0tCTqlmdrB$wjyLzzX_RCv | 294 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110033 | 5845976 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d8 | 0tCTqlmdrB$wjyLzzX_RCs | 295 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110034 | 5845977 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d9 | 0tCTqlmdrB$wjyLzzX_RCt | 296 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110035 | 5845978 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933da | 0tCTqlmdrB$wjyLzzX_RCq | 297 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110036 | 5845979 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933db | 0tCTqlmdrB$wjyLzzX_RCr | 298 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110037 | 5845980 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933dc | 0tCTqlmdrB$wjyLzzX_RCo | 299 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110038 | 5845989 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e5 | 0tCTqlmdrB$wjyLzzX_RCB | 300 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110039 | 5845990 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e6 | 0tCTqlmdrB$wjyLzzX_RC8 | 301 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110040 | 5845991 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e7 | 0tCTqlmdrB$wjyLzzX_RC9 | 302 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110041 | 5845992 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e8 | 0tCTqlmdrB$wjyLzzX_RC6 | 303 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110042 | 5846344 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593548 | 0tCTqlmdrB$wjyLzzX_RMc | 304 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110043 | 5851643 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005949fb | 0tCTqlmdrB$wjyLzzX_SaL | 305 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110044 | 5851659 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00594a0b | 0tCTqlmdrB$wjyLzzX_Shb | 306 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110027 | 7892081 | e8eff5a9-5f27-4639-ab0a-c25e9dd4ee92-007863ba | 3ex$MfNoT6EQiAmbwTh8qe | 307 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110029 | 8792866 | 56a8ccba-2dbe-49c0-8a13-c71429529403-00862b22 | 1MgCowBRv9m8eJnnGfrByX | 308 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110101 | 5843144 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005928c8 | 0tCTqlmdrB$wjyLzzX_QWc | 320 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110102 | 5843145 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005928c9 | 0tCTqlmdrB$wjyLzzX_QWd | 321 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110111 | 5845383 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593187 | 0tCTqlmdrB$wjyLzzX_R5f | 331 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110112 | 5845384 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593188 | 0tCTqlmdrB$wjyLzzX_R5c | 332 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110113 | 5845385 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593189 | 0tCTqlmdrB$wjyLzzX_R5d | 333 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110114 | 8570346 | 2883228c-23b5-429d-81cc-de136da916bf-0082c5ea | 0eWoAC8xL2dO7CtXDjAzDL | 334 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110103 | 8680371 | 3abc24a0-be39-414b-9ec0-3241a1b70f8f-008473b3 | 0wl2IWlZb1Ivx0Ca6XCtmy | 335 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110123 | 10017602 | f2e7dbe8-de47-4525-bb95-67bad0ceef4e-0098bd56 | 3ovzletaT59RkLPxhGLb8O | 458 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/400+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110049 | 5842547 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592673 | 0tCTqlmdrB$wjyLzzX_QQT | 459 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110050 | 5842548 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592674 | 0tCTqlmdrB$wjyLzzX_QQQ | 460 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110051 | 5842549 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592675 | 0tCTqlmdrB$wjyLzzX_QQR | 461 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110052 | 5842550 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592676 | 0tCTqlmdrB$wjyLzzX_QQO | 462 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110053 | 5842737 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592731 | 0tCTqlmdrB$wjyLzzX_QVV | 463 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110054 | 5842738 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592732 | 0tCTqlmdrB$wjyLzzX_QVS | 464 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110055 | 5842739 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592733 | 0tCTqlmdrB$wjyLzzX_QVT | 465 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110056 | 5842740 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592734 | 0tCTqlmdrB$wjyLzzX_QVQ | 466 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110057 | 5842772 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592754 | 0tCTqlmdrB$wjyLzzX_QUw | 467 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110058 | 5842773 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592755 | 0tCTqlmdrB$wjyLzzX_QUx | 468 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110059 | 5842774 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592756 | 0tCTqlmdrB$wjyLzzX_QUu | 469 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110061 | 5842781 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059275d | 0tCTqlmdrB$wjyLzzX_QUp | 470 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110062 | 5842782 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059275e | 0tCTqlmdrB$wjyLzzX_QUm | 471 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110063 | 5842783 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059275f | 0tCTqlmdrB$wjyLzzX_QUn | 472 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110064 | 5842784 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592760 | 0tCTqlmdrB$wjyLzzX_QUE | 473 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110065 | 5842812 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059277c | 0tCTqlmdrB$wjyLzzX_QUI | 474 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110066 | 5842813 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059277d | 0tCTqlmdrB$wjyLzzX_QUJ | 475 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110067 | 5842814 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059277e | 0tCTqlmdrB$wjyLzzX_QUG | 476 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110068 | 5842815 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059277f | 0tCTqlmdrB$wjyLzzX_QUH | 477 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | — | — | — | — | — | — |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110069 | 5842843 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059279b | 0tCTqlmdrB$wjyLzzX_QTr | 478 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110070 | 5842844 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059279c | 0tCTqlmdrB$wjyLzzX_QTo | 479 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110073 | 5842876 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005927bc | 0tCTqlmdrB$wjyLzzX_QTI | 480 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110074 | 5842877 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005927bd | 0tCTqlmdrB$wjyLzzX_QTJ | 481 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110075 | 5842878 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005927be | 0tCTqlmdrB$wjyLzzX_QTG | 482 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110076 | 5842879 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005927bf | 0tCTqlmdrB$wjyLzzX_QTH | 483 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110082 | 5842941 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005927fd | 0tCTqlmdrB$wjyLzzX_QSJ | 484 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110083 | 5842942 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005927fe | 0tCTqlmdrB$wjyLzzX_QSG | 485 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | — | — | — | — | — | — |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110085 | 5843058 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592872 | 0tCTqlmdrB$wjyLzzX_QYS | 486 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110086 | 5843059 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592873 | 0tCTqlmdrB$wjyLzzX_QYT | 487 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110087 | 5843060 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592874 | 0tCTqlmdrB$wjyLzzX_QYQ | 488 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110088 | 5843061 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592875 | 0tCTqlmdrB$wjyLzzX_QYR | 489 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110089 | 5843062 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592876 | 0tCTqlmdrB$wjyLzzX_QYO | 490 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110091 | 5843064 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592878 | 0tCTqlmdrB$wjyLzzX_QYM | 491 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110109 | 5843212 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059290c | 0tCTqlmdrB$wjyLzzX_QdY | 492 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110110 | 5843215 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059290f | 0tCTqlmdrB$wjyLzzX_QdX | 493 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110116 | 5845464 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005931d8 | 0tCTqlmdrB$wjyLzzX_R4s | 494 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110117 | 5845465 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005931d9 | 0tCTqlmdrB$wjyLzzX_R4t | 495 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110118 | 5845466 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005931da | 0tCTqlmdrB$wjyLzzX_R4q | 496 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110121 | 6394376 | c872913a-c785-4643-aa7e-6f0a1fd6de37-00619208 | 38Sf4wnuL6Gwf_RmeVjqm$ | 497 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110120 | 8160530 | afd8fb35-19f9-479f-b1bf-605a8c8005fb-007c81e3 | 2lsFir6Vb7dx6$O5gC$8GO | 498 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110071 | 8462305 | ac4131d0-4c16-4cad-b06f-b20f8f429630-00811fe1 | 2iGJ7GJ1PChR1liW_FmudH | 499 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |