BIM Asset Data Completion Across All Levels and Phases
Tracks how the overall and per-category completion has moved across each refresh of the BIM data. Hover for the exact date and percentage; expand the snapshot list below to see every recorded point.
Click a bar to drill into that category.
Click a phase name to filter by phase. Click a category cell to drill the asset table to that slice.
Click a level name to filter the whole dashboard. Click a category cell to drill the asset table to that slice.
| Basic | FM | BOS | Element Specific | Uncategorised | All | |
|---|---|---|---|---|---|---|
| Level B2 | — | — | — | — | — | — |
| Level B1 | 90% | 0% | 76% | — | 89% | 60% |
| Level 00 | — | — | — | — | — | — |
| Level 00M | — | — | — | — | — | — |
| Level 01 | — | — | — | — | — | — |
| Level 02 | — | — | — | — | — | — |
| Level 03 | — | — | — | — | — | — |
| Level 04 | — | — | — | — | — | — |
| Level 05 | — | — | — | — | — | — |
| Level 06 | — | — | — | — | — | — |
| Level 07 | — | — | — | — | — | — |
| Level 08 | — | — | — | — | — | — |
| Level 09 | — | — | — | — | — | — |
| Level 10 | — | — | — | — | — | — |
| Level 11 | 86% | 8% | 62% | — | 100% | 62% |
| Level 12 | 87% | 0% | 33% | — | 75% | 53% |
| SSY 17.900 | — | — | — | — | — | — |
| Datum | — | — | — | — | — | — |
| (no level) | — | — | — | — | — | — |
One row per BIM element. Reflects the active filters. Click a row to open that asset’s full record.
| File | Phase | Level | Asset Category | Asset Code | Element ID | GUID | IFC GUID | Row # | Asset Description | Family | Type | Maint. | Basic | FM | BOS | Element-Spec | Uncat. | Overall |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990031 | 6160552 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e00a8 | — | 12 | Air terminals | HL_ExtractBellMouth_DuctMtdRec1HorRecCon2 | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990005 | 7164049 | a696fbec-5a70-4f2e-b11b-614fc3898753-006d5091 | — | 13 | Air terminals | HL_ExtractBellMouth_DuctMtdRec1HorRecCon2 | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990020 | 6160433 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0031 | — | 14 | Air terminals | HL_ExtractBellMouth_DuctMtdRnd1HorRndCon | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990021 | 6160460 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e004c | — | 15 | Air terminals | HL_ExtractBellMouth_DuctMtdRnd1HorRndCon | Generic | No | 87% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990023 | 6160464 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0050 | — | 16 | Air terminals | HL_ExtractBellMouth_DuctMtdRnd1HorRndCon | Generic | No | 87% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990025 | 6160520 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0088 | — | 17 | Air terminals | HL_ExtractBellMouth_DuctMtdRnd1HorRndCon | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990026 | 6160523 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e008b | — | 18 | Air terminals | HL_ExtractBellMouth_DuctMtdRnd1HorRndCon | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990028 | 6160543 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e009f | — | 19 | Air terminals | HL_ExtractBellMouth_DuctMtdRnd1HorRndCon | Generic | No | 100% | 0% | 100% | — | 89% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990033 | 6160562 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e00b2 | — | 20 | Air terminals | HL_ExtractBellMouth_DuctMtdRnd1HorRndCon | Generic | No | 87% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990039 | 6160631 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e00f7 | — | 21 | Air terminals | HL_ExtractBellMouth_DuctMtdRnd1HorRndCon | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990045 | 6163435 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0beb | 0mwxlEfGD8MQCn$HjSTxZJ | 22 | Air terminals | HL_ExtractBellMouth_DuctMtdRnd1HorRndCon | Generic | No | 100% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990022 | 6874529 | 7841f1e2-1e1a-486b-8dfb-d4e5a2c6a2c2-0068e5a1 | — | 23 | Air terminals | HL_ExtractBellMouth_DuctMtdRnd1HorRndCon | Generic | No | 87% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990015 | 6160401 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0011 | — | 24 | Air terminals | HL_SupplyDiffuser_CeilingRoundPlenum1HorizontalRoundConnection1 | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990016 | 6160410 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e001a | — | 25 | Air terminals | HL_SupplyDiffuser_CeilingRoundPlenum1HorizontalRoundConnection1 | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990017 | 6160419 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0023 | — | 26 | Air terminals | HL_SupplyDiffuser_CeilingRoundPlenum1HorizontalRoundConnection1 | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990018 | 6160431 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e002f | — | 27 | Air terminals | HL_SupplyDiffuser_CeilingRoundPlenum1HorizontalRoundConnection1 | Generic | No | 87% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990024 | 6160514 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0082 | — | 28 | Air terminals | HL_SupplyDiffuser_CeilingRoundPlenum1HorizontalRoundConnection1 | Generic | No | 87% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990041 | 6160771 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0183 | — | 29 | Air terminals | HL_SupplyDiffuser_CeilingRoundPlenum1HorizontalRoundConnection1 | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990050 | 6163904 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0dc0 | — | 30 | Air terminals | HL_SupplyDiffuser_CeilingRoundPlenum1HorizontalRoundConnection1 | Generic | No | 87% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990051 | 6163907 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0dc3 | — | 31 | Air terminals | HL_SupplyDiffuser_CeilingRoundPlenum1HorizontalRoundConnection1 | Generic | No | 87% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990052 | 6866766 | f07f7328-1ce6-47f1-a2fa-0ed6c5190baf-0068c74e | — | 32 | Air terminals | HL_SupplyDiffuser_CeilingRoundPlenum1HorizontalRoundConnection1 | Generic | No | 87% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990053 | 6868024 | f07f7328-1ce6-47f1-a2fa-0ed6c5190baf-0068cc38 | — | 33 | Air terminals | HL_SupplyDiffuser_CeilingRoundPlenum1HorizontalRoundConnection1 | Generic | No | 87% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990040 | 6160766 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e017e | — | 34 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon2 | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990042 | 6160776 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0188 | — | 35 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon2 | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990027 | 6160538 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e009a | — | 36 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990029 | 6160544 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e00a0 | — | 37 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990030 | 6160545 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e00a1 | — | 38 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990032 | 6160553 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e00a9 | — | 39 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990034 | 6160571 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e00bb | — | 40 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990035 | 6160572 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e00bc | — | 41 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990036 | 6160626 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e00f2 | — | 42 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990037 | 6160627 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e00f3 | — | 43 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990038 | 6160628 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e00f4 | — | 44 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon | Generic | No | 100% | 0% | 100% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Air Terminals | CAV-2990044 | 6163425 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0be1 | 0mwxlEfGD8MQCn$HjSTxZP | 45 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon | Generic | No | 100% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6660256 | a82f8ffd-d50d-4820-8d54-f99cc6e15c4d-0065a0a0 | 2eBu$zrGr888rK_Pp6XFpj | 3 | Standard socket outlets | GEN_Data_Outlet | Wall Mounted | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6660357 | a82f8ffd-d50d-4820-8d54-f99cc6e15c4d-0065a105 | 2eBu$zrGr888rK_Pp6XFr8 | 4 | Standard socket outlets | GEN_Data_Outlet | Wall Mounted | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6660369 | a82f8ffd-d50d-4820-8d54-f99cc6e15c4d-0065a111 | 2eBu$zrGr888rK_Pp6XFrS | 5 | Standard socket outlets | GEN_Data_Outlet | Wall Mounted | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6660377 | a82f8ffd-d50d-4820-8d54-f99cc6e15c4d-0065a119 | 2eBu$zrGr888rK_Pp6XFrK | 6 | Standard socket outlets | GEN_Data_Outlet | Wall Mounted | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6661774 | a82f8ffd-d50d-4820-8d54-f99cc6e15c4d-0065a68e | 2eBu$zrGr888rK_Pp6XFh3 | 7 | Standard socket outlets | GEN_Data_Outlet | Wall Mounted | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6716430 | e5c3db3b-64eb-41b6-9736-00d67c8ba075-00667c0e | — | 8 | Standard socket outlets | GEN_Data_Outlet | Wall Mounted | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6844380 | bc76fbef-b0bb-4e74-b63a-e5a210b65c19-00686fdc | — | 12 | Standard socket outlets | GEN_Data_Outlet | Wall Mounted | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 7117252 | d4251afe-ce13-440a-baae-d45e2bd384cf-006c99c4 | — | 13 | Standard socket outlets | GEN_Data_Outlet | Wall Mounted | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | — | 7403756 | bdcf219e-3f50-4bf6-993d-24dd5df51e69-0070f8ec | — | 14 | Standard socket outlets | GEN_Data_Outlet | Wall Mounted | No | 67% | 0% | 67% | — | 63% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | — | 7403780 | bdcf219e-3f50-4bf6-993d-24dd5df51e69-0070f904 | — | 15 | Standard socket outlets | GEN_Data_Outlet | Wall Mounted | No | 67% | 0% | 67% | — | 63% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159912 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe28 | — | 52 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159913 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe29 | — | 53 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159914 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe2a | — | 54 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159915 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe2b | — | 55 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160021 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe95 | — | 56 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160023 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe97 | — | 57 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160025 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe99 | — | 58 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160029 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe9d | — | 59 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160031 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe9f | — | 60 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160034 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfea2 | — | 61 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160035 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfea3 | — | 62 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160167 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dff27 | — | 63 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160169 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dff29 | — | 64 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160170 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dff2a | — | 65 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 100% | 0% | 100% | — | 89% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160171 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dff2b | — | 66 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6163418 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0bda | 0mwxlEfGD8MQCn$HjSTxZY | 67 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 93% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6163441 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0bf1 | — | 68 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6163449 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0bf9 | — | 69 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6163462 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0c06 | 0mwxlEfGD8MQCn$HjSTxy_ | 70 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched | No | 93% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159904 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe20 | — | 71 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched Cleaners | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159906 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe22 | — | 72 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched Cleaners | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159926 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe36 | — | 74 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched Cleaners | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159928 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe38 | 0mwxlEfGD8MQCn$HjST4q0 | 75 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched Cleaners | No | 93% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159929 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe39 | — | 76 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched Cleaners | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159930 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe3a | — | 77 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched Cleaners | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159959 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe57 | — | 78 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched Cleaners | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160033 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfea1 | — | 79 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched Cleaners | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160181 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dff35 | — | 80 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched Cleaners | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6163420 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0bdc | 0mwxlEfGD8MQCn$HjSTxZa | 81 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched Cleaners | No | 93% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6163464 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0c08 | — | 82 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 1 Gang Switched Cleaners | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159895 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe17 | — | 83 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 100% | 0% | 100% | — | 89% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159896 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe18 | — | 84 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159898 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe1a | — | 85 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159899 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe1b | — | 86 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159900 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe1c | — | 87 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159901 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe1d | — | 88 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159902 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe1e | — | 89 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159903 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe1f | — | 90 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159909 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe25 | — | 91 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159910 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe26 | — | 92 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159918 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe2e | — | 93 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159919 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe2f | — | 94 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159920 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe30 | — | 95 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159921 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe31 | — | 96 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159931 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe3b | — | 97 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159945 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe49 | — | 98 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159947 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe4b | — | 99 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159950 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe4e | — | 100 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159952 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe50 | — | 101 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159955 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe53 | — | 102 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159957 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe55 | — | 103 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6159967 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe5f | — | 104 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160018 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe92 | — | 105 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6160028 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005dfe9c | — | 106 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164073 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e69 | — | 107 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164075 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e6b | — | 108 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164076 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e6c | — | 109 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164078 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e6e | — | 110 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164079 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e6f | — | 111 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 100% | 0% | 100% | — | 89% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164081 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e71 | — | 112 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164083 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e73 | — | 113 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164085 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e75 | — | 114 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 100% | 0% | 100% | — | 89% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164086 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e76 | — | 115 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164088 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e78 | — | 116 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164089 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e79 | — | 117 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164091 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e7b | — | 118 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164092 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e7c | — | 119 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164094 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e7e | — | 120 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164108 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e8c | — | 121 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164110 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0e8e | — | 122 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164288 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f40 | 0mwxlEfGD8MQCn$HjSTxnu | 123 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164290 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f42 | 0mwxlEfGD8MQCn$HjSTxnw | 124 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164291 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f43 | 0mwxlEfGD8MQCn$HjSTxnx | 125 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164292 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f44 | 0mwxlEfGD8MQCn$HjSTxny | 126 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164296 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f48 | 0mwxlEfGD8MQCn$HjSTxnm | 127 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164298 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f4a | 0mwxlEfGD8MQCn$HjSTxno | 128 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164299 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f4b | — | 129 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 87% | 0% | 100% | — | 89% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164300 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f4c | — | 130 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164301 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f4d | 0mwxlEfGD8MQCn$HjSTxnr | 131 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164302 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f4e | 0mwxlEfGD8MQCn$HjSTxns | 132 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164303 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f4f | 0mwxlEfGD8MQCn$HjSTxnt | 133 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164304 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f50 | 0mwxlEfGD8MQCn$HjSTxne | 134 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164305 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f51 | 0mwxlEfGD8MQCn$HjSTxnf | 135 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164306 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f52 | 0mwxlEfGD8MQCn$HjSTxng | 136 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164307 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f53 | 0mwxlEfGD8MQCn$HjSTxnh | 137 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164308 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f54 | 0mwxlEfGD8MQCn$HjSTxni | 138 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164312 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f58 | 0mwxlEfGD8MQCn$HjSTxnW | 139 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6164313 | 30ebbbce-a503-4859-a331-fd1b5c29b338-005e0f59 | 0mwxlEfGD8MQCn$HjSTxnX | 140 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6226788 | 63494105-8f05-4eca-98a5-7440e6f66eb0-005f0364 | 1ZIK45ZmLEofYbT43cgMtK | 141 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6657239 | a82f8ffd-d50d-4820-8d54-f99cc6e15c4d-006594d7 | 2eBu$zrGr888rK_Pp6XCYQ | 142 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6723658 | 8f0d7562-88b1-4b2f-b887-c0056653012a-0066984a | — | 143 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6724736 | 8f0d7562-88b1-4b2f-b887-c0056653012a-00669c80 | — | 144 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 7105227 | 4c1dcdac-3f46-4883-aa4a-7bbc86fe34c3-006c69bd | — | 145 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 7105228 | 4c1dcdac-3f46-4883-aa4a-7bbc86fe34c3-006c69be | — | 146 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 7105231 | 4c1dcdac-3f46-4883-aa4a-7bbc86fe34c3-006c6a09 | — | 147 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 7105232 | 4c1dcdac-3f46-4883-aa4a-7bbc86fe34c3-006c6a0a | — | 148 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 7105233 | 4c1dcdac-3f46-4883-aa4a-7bbc86fe34c3-006c6a1c | — | 149 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 7105234 | 4c1dcdac-3f46-4883-aa4a-7bbc86fe34c3-006c6a1d | — | 150 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 7105482 | 4c1dcdac-3f46-4883-aa4a-7bbc86fe34c3-006c6bca | — | 151 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 7105483 | 4c1dcdac-3f46-4883-aa4a-7bbc86fe34c3-006c6bcb | — | 152 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 7105949 | 4c1dcdac-3f46-4883-aa4a-7bbc86fe34c3-006c6d9d | — | 153 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 7105984 | 4c1dcdac-3f46-4883-aa4a-7bbc86fe34c3-006c6dc0 | — | 154 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 7106028 | 4c1dcdac-3f46-4883-aa4a-7bbc86fe34c3-006c6dec | — | 155 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 7106030 | 4c1dcdac-3f46-4883-aa4a-7bbc86fe34c3-006c6dee | — | 156 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | — | 7646386 | 0bc88e05-a031-431b-9f20-c262e928b45d-0074acb2 | — | 157 | Standard socket outlets | HL_SocketOutlet_WallRecessed | 2 Gang Switched | — | 67% | 0% | 67% | — | 50% | 0% |
| KXC-A-001-X-PME-6000-M3000 | Phase 1 | Level B1 - FFL | Electrical Fixtures | N/A | 6638549 | a82f8ffd-d50d-4820-8d54-f99cc6e15c4d-00654bd5 | 2eBu$zrGr888rK_Pp6X1UO | 231 | Standard socket outlets | PD_ELFc_Electrical-Fixture_Socket-Commando-TPN_v22.0.1 | Commando Socket TPN | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3001 | Phase 2 | LEVEL B1 - UPPER | Air Terminals | — | 7004728 | 5ce865fb-9279-4765-9254-ba7ef0f20e25-006ae238 | — | 323 | Air diffusers | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm2HorRndCon | Generic | No | 93% | 0% | 67% | — | 88% | 0% |
| KXC-A-001-X-PME-6000-M3001 | Phase 2 | Level B1 - FFL | Duct Accessories | — | 15378130 | db6c303e-f33e-4411-8582-ae7f86a9e2eb-00eaa6d2 | — | 47 | Rectangular attenuators | HL_Attenuator_RectangularRectangularConnections | SG01V/3C/L/S | No | 93% | 17% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3001 | Phase 3 | Level B1 - FFL | Duct Accessories | — | 15464346 | 18df54f3-a4b7-49fd-ad88-9260645b1e5d-00ebf58f | — | 48 | Rectangular attenuators | HL_Attenuator_RectangularRectangularConnections | SG01V/3C/L/S | No | 93% | 17% | 67% | — | 75% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5849338 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005940fa | 0tCTqlmdrB$wjyLzzX_S0K | 7 | Air terminals | HL_DuctCap_ExtractRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845620 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593274 | 0tCTqlmdrB$wjyLzzX_RAQ | 13 | Air terminals | HL_DuctCap_SupplyRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845749 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005932f5 | 0tCTqlmdrB$wjyLzzX_R8R | 14 | Air terminals | HL_DuctCap_SupplyRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845750 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005932f6 | 0tCTqlmdrB$wjyLzzX_R8O | 15 | Air terminals | HL_DuctCap_SupplyRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5851666 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00594a12 | 0tCTqlmdrB$wjyLzzX_Shy | 16 | Air terminals | HL_DuctCap_SupplyRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5851667 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00594a13 | 0tCTqlmdrB$wjyLzzX_Shz | 17 | Air terminals | HL_DuctCap_SupplyRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 6999410 | bee7027b-b3a4-4db6-9809-bdf014a671a6-006acd72 | 2_vm9xiwHDjfW9lV0KpBpK | 18 | Air terminals | HL_DuctCap_SupplyRectangular | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845613 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059326d | 0tCTqlmdrB$wjyLzzX_RA3 | 29 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845614 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059326e | 0tCTqlmdrB$wjyLzzX_RA0 | 30 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845615 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059326f | 0tCTqlmdrB$wjyLzzX_RA1 | 31 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845616 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593270 | 0tCTqlmdrB$wjyLzzX_RAU | 32 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845617 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593271 | 0tCTqlmdrB$wjyLzzX_RAV | 33 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845618 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593272 | 0tCTqlmdrB$wjyLzzX_RAS | 34 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845619 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593273 | 0tCTqlmdrB$wjyLzzX_RAT | 35 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845622 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593276 | 0tCTqlmdrB$wjyLzzX_RAO | 36 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845623 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593277 | 0tCTqlmdrB$wjyLzzX_RAP | 37 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845624 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593278 | 0tCTqlmdrB$wjyLzzX_RAM | 38 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845625 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593279 | 0tCTqlmdrB$wjyLzzX_RAN | 39 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845626 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059327a | 0tCTqlmdrB$wjyLzzX_RAK | 40 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845627 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059327b | 0tCTqlmdrB$wjyLzzX_RAL | 41 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845628 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059327c | 0tCTqlmdrB$wjyLzzX_RAI | 42 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845629 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059327d | 0tCTqlmdrB$wjyLzzX_RAJ | 43 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845630 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059327e | 0tCTqlmdrB$wjyLzzX_RAG | 44 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845759 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005932ff | 0tCTqlmdrB$wjyLzzX_R8H | 45 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845760 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593300 | 0tCTqlmdrB$wjyLzzX_RFk | 46 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845761 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593301 | 0tCTqlmdrB$wjyLzzX_RFl | 47 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 5845762 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593302 | 0tCTqlmdrB$wjyLzzX_RFi | 48 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 7111073 | 4a4fdd3b-c967-41da-abbc-b65c6c4e2024-006c81a1 | 1AJzqxoMT1sgkyjbni8g65 | 49 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 8691385 | 8a104142-4934-4f91-89b4-d65f750a59db-00849eb9 | 2A4452IJHFaOcqrbzrZiTY | 50 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 8856319 | 02260a24-2a90-407d-af75-b8ce96f0144a-008722ff | 029WeaAf10VQzrkCwMTpQr | 51 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 8856320 | 02260a24-2a90-407d-af75-b8ce96f0144a-00872300 | 029WeaAf10VQzrkCwMTpTA | 52 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 8856530 | 02260a24-2a90-407d-af75-b8ce96f0144a-008723d2 | 029WeaAf10VQzrkCwMTpUO | 53 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 8856537 | 02260a24-2a90-407d-af75-b8ce96f0144a-008723d9 | 029WeaAf10VQzrkCwMTpUJ | 54 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 80% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | — | 11164916 | c5ed83c5-efb3-49c1-917b-4938e264cecb-00aa5cf4 | 35xOF5xxD9mP5xIJZYpf8$ | 55 | Air terminals | HL_DuctCap_SupplyRound | Generic | No | 73% | 0% | 67% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110005 | 8501267 | e74a31ce-e034-4065-b91c-42755f5f3b0e-0081b813 | 3dIZ7Eu3H0PRaSGdLVteCT | 87 | Air terminals | HL_ExtractGrille_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110004 | 8501295 | e74a31ce-e034-4065-b91c-42755f5f3b0e-0081b82f | 3dIZ7Eu3H0PRaSGdLVteCX | 88 | Air terminals | HL_ExtractGrille_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110003 | 8501950 | e74a31ce-e034-4065-b91c-42755f5f3b0e-0081babe | 3dIZ7Eu3H0PRaSGdLVte6m | 89 | Air terminals | HL_ExtractGrille_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110001 | 8501968 | e74a31ce-e034-4065-b91c-42755f5f3b0e-0081bad0 | 3dIZ7Eu3H0PRaSGdLVte7U | 90 | Air terminals | HL_ExtractGrille_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110002 | 8501969 | e74a31ce-e034-4065-b91c-42755f5f3b0e-0081bad1 | 3dIZ7Eu3H0PRaSGdLVte7V | 91 | Air terminals | HL_ExtractGrille_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110007 | 5845982 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933de | 0tCTqlmdrB$wjyLzzX_RCm | 93 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110008 | 5845983 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933df | 0tCTqlmdrB$wjyLzzX_RCn | 94 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110009 | 5845984 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e0 | 0tCTqlmdrB$wjyLzzX_RCE | 95 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110010 | 5845985 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e1 | 0tCTqlmdrB$wjyLzzX_RCF | 96 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110011 | 5845986 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e2 | 0tCTqlmdrB$wjyLzzX_RCC | 97 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110012 | 5845987 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e3 | 0tCTqlmdrB$wjyLzzX_RCD | 98 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110013 | 5845988 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e4 | 0tCTqlmdrB$wjyLzzX_RCA | 99 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110014 | 5845993 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e9 | 0tCTqlmdrB$wjyLzzX_RC7 | 100 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110015 | 5849308 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005940dc | 0tCTqlmdrB$wjyLzzX_S0o | 101 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110006 | 7884485 | b38a3c8b-6e09-4076-8860-4a1d7537e9b0-007825a3 | 2pYZoBRWb0TeXWIXrrJymJ | 102 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110016 | 8440762 | 9b657c34-f792-47f0-9994-4968684b803a-0080cbba | 2RPNmqzv97y9cKIMXeoqk0 | 103 | Air terminals | HL_ExtractGrille_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110020 | 5845805 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-0059332d | 0tCTqlmdrB$wjyLzzX_RF3 | 243 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110021 | 5845844 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593354 | 0tCTqlmdrB$wjyLzzX_REw | 244 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110022 | 5845845 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593355 | 0tCTqlmdrB$wjyLzzX_REx | 245 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110023 | 5845846 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593356 | 0tCTqlmdrB$wjyLzzX_REu | 246 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110024 | 5845847 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593357 | 0tCTqlmdrB$wjyLzzX_REv | 247 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110019 | 8479660 | 253350e3-f6aa-49c8-8be9-6e40f7edee51-008163ac | 0bCr3Zzgf9o8lfRa3tR8tz | 248 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110122 | 8507923 | 721f6a28-4a25-462c-b61b-25250538b084-0081d213 | 1o7seeIYL6BBOR9IK5kMAN | 249 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110017 | 8507975 | 721f6a28-4a25-462c-b61b-25250538b084-0081d247 | 1o7seeIYL6BBOR9IK5kMB3 | 250 | Air terminals | HL_SupplyDiffuser_CeilMtdLinFaceLinPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110025 | 5845968 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d0 | 0tCTqlmdrB$wjyLzzX_RC_ | 289 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110026 | 5845969 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d1 | 0tCTqlmdrB$wjyLzzX_RC$ | 290 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110028 | 5845971 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d3 | 0tCTqlmdrB$wjyLzzX_RCz | 291 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110030 | 5845973 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d5 | 0tCTqlmdrB$wjyLzzX_RCx | 292 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110031 | 5845974 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d6 | 0tCTqlmdrB$wjyLzzX_RCu | 293 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110032 | 5845975 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d7 | 0tCTqlmdrB$wjyLzzX_RCv | 294 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110033 | 5845976 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d8 | 0tCTqlmdrB$wjyLzzX_RCs | 295 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110034 | 5845977 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933d9 | 0tCTqlmdrB$wjyLzzX_RCt | 296 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110035 | 5845978 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933da | 0tCTqlmdrB$wjyLzzX_RCq | 297 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110036 | 5845979 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933db | 0tCTqlmdrB$wjyLzzX_RCr | 298 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110037 | 5845980 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933dc | 0tCTqlmdrB$wjyLzzX_RCo | 299 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110038 | 5845989 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e5 | 0tCTqlmdrB$wjyLzzX_RCB | 300 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110039 | 5845990 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e6 | 0tCTqlmdrB$wjyLzzX_RC8 | 301 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110040 | 5845991 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e7 | 0tCTqlmdrB$wjyLzzX_RC9 | 302 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110041 | 5845992 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005933e8 | 0tCTqlmdrB$wjyLzzX_RC6 | 303 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110042 | 5846344 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593548 | 0tCTqlmdrB$wjyLzzX_RMc | 304 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110043 | 5851643 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005949fb | 0tCTqlmdrB$wjyLzzX_SaL | 305 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110044 | 5851659 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00594a0b | 0tCTqlmdrB$wjyLzzX_Shb | 306 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110027 | 7892081 | e8eff5a9-5f27-4639-ab0a-c25e9dd4ee92-007863ba | 3ex$MfNoT6EQiAmbwTh8qe | 307 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110029 | 8792866 | 56a8ccba-2dbe-49c0-8a13-c71429529403-00862b22 | 1MgCowBRv9m8eJnnGfrByX | 308 | Air terminals | HL_SupplyDiffuser_CeilMtdRecFaceRecPlnm1HorRndCon | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110101 | 5843144 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005928c8 | 0tCTqlmdrB$wjyLzzX_QWc | 320 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110102 | 5843145 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-005928c9 | 0tCTqlmdrB$wjyLzzX_QWd | 321 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110111 | 5845383 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593187 | 0tCTqlmdrB$wjyLzzX_R5f | 331 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110112 | 5845384 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593188 | 0tCTqlmdrB$wjyLzzX_R5c | 332 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110113 | 5845385 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00593189 | 0tCTqlmdrB$wjyLzzX_R5d | 333 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110114 | 8570346 | 2883228c-23b5-429d-81cc-de136da916bf-0082c5ea | 0eWoAC8xL2dO7CtXDjAzDL | 334 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110103 | 8680371 | 3abc24a0-be39-414b-9ec0-3241a1b70f8f-008473b3 | 0wl2IWlZb1Ivx0Ca6XCtmy | 335 | Air terminals | HL_SupplyDiffuser_CeilMtdRndFaceRndPlnm1HorRndCon1 | Generic | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110123 | 10017602 | f2e7dbe8-de47-4525-bb95-67bad0ceef4e-0098bd56 | 3ovzletaT59RkLPxhGLb8O | 458 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/400+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110049 | 5842547 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592673 | 0tCTqlmdrB$wjyLzzX_QQT | 459 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110050 | 5842548 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592674 | 0tCTqlmdrB$wjyLzzX_QQQ | 460 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110051 | 5842549 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592675 | 0tCTqlmdrB$wjyLzzX_QQR | 461 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110052 | 5842550 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592676 | 0tCTqlmdrB$wjyLzzX_QQO | 462 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110053 | 5842737 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592731 | 0tCTqlmdrB$wjyLzzX_QVV | 463 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110054 | 5842738 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592732 | 0tCTqlmdrB$wjyLzzX_QVS | 464 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110055 | 5842739 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592733 | 0tCTqlmdrB$wjyLzzX_QVT | 465 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110056 | 5842740 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592734 | 0tCTqlmdrB$wjyLzzX_QVQ | 466 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110057 | 5842772 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592754 | 0tCTqlmdrB$wjyLzzX_QUw | 467 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110058 | 5842773 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592755 | 0tCTqlmdrB$wjyLzzX_QUx | 468 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |
| KXC-A-001-X-PME-6000-M3010 | Phase 1 | LEVEL 11 - FFL | Air Terminals | CAV-2110059 | 5842774 | 3731dd2f-c27d-4bff-ab7c-57df61a080ee-00592756 | 0tCTqlmdrB$wjyLzzX_QUu | 469 | Air terminals | Waterloo_SD5-C+CPB_SupplyDiffuserRound | SD5/C/500+CPB | No | 87% | 0% | 100% | — | 100% | 0% |